Set the Frequency of Dispatcher Scans for a Servlet Gateway
If you use Servlet Gateways, you can specify
how often they scan dispatchers for their current status. Traffic
is routed to another dispatcher if the first one fails.
Use the following parameters:
- pingPeriod
Specifies, in seconds, the interval between scans for the state of dispatchers.
Valid settings are 1 to 2147483647. Settings less than 5 may consume too many resources (CPU time and network bandwidth). The default setting is 180.
- fileCheckPeriod
Specifies, in seconds, the interval between startup configuration file checks for new dispatchers.
Valid settings are 1 to 2147483647. The default is 30.
For information about gateways and URIs, see the IBM Cognos Business Intelligence Installation and Configuration Guide.